PRODUCT
Connect You With Vast Splendidness By Using
Convenient And Accessible Clean Energy

THE WORLD 1st SODIUM-ION BATTERY POWERED ON-LINE UPS
Vigor Series 10-40kVA 3 Phase UPS
• High Reliability
DSP central control, stable and reliable;
Input power factor correction technology, input power factor up to 0.99;
• Powered by Sodium-Ion batteries
Top class sodium-ion cells with super high rate performance;
Extra safety protections from sodium cell to battery pack;
Super fast recharge within 1 hour ( to 90% capacity );
• Intelligent Management
Specific firmware control setting , tailored to sodium-ion batteries;
Built-in dual-level BMS ,real-time manage battery operation status ,protect from over-charger,over-discharge, over-temperature etc.;
Support Wifi remote monitoring for battery status;
Multiple communication options for RS485 ,USB, SNMP/dry contact cards etc.;
• High Availability
Supports rigorous loads, generator compatible;
Parallel up to 4 units;
Supports common battery;
• High Accessibility
Supports rack and tower installations ,available for external battery packs;
4.3” touchable LCD with real-time monitoring and easily setting;
Product specification
Model
Vigor 10K-RT
Vigor 15K-RT
Vigor 20K-RT
Vigor 30K-RT
Vigor 40K-RT
Capacity (VA/W)
10k/10k
15k/15k
20k/20k
30k/30k
40k/40k
Phase
1:1 / 3:1 / 3:3
3:3
INPUT
Nominal Voltage
220/230/240Vac, (1Ph+N+PE)
380/400/415Vac, (3Ph+N+PE)
380/400/415Vac, (3Ph+N+PE)
Dulle input
Support
Operating voltage range
138~485Vac for 40%load
305~485Vac for full-load
Operating frequency range
40Hz-70Hz
THDi
3% (100%linear load)
Bypass voltage range
Max. voltage: 220V: +25%(optional +10%,+15%,+20% )
230V: +20%(optional +10%,+15% )
240V: +15%(optional +10%)
Min. voltage: -45% (optional-10%, -20%,-30%)
Bypass frequency range
Frequency protection range:±10%
Generator input
Support
OUTPUT
Rated voltage
220/230/240Vac, (1Ph+N+PE)
380/400/415Vac, (3Ph+N+PE)
380/400/415Vac, (3Ph+N+PE)
Power factor
1.0
Voltage regulation
± 1%
Output frequency
Line mode
±1%/±2%/±4%/±5%/±10% of the rated frequency(optional)
Output frequency
Bat. mode
50/60Hz ± 0.1%
Crest factor
3 : 1
THDu
≤2% (linear load); ≤4% (non-linear load)
Efficiency(Max)
94.6%
95.3%
95.6%
BATTERY
Battery type
Sodium-ion
Phase
Positive and negative voltage
Battery model
(Bx192064Na-RT-G1)*2
(Bx240064Na-RT-G1)*2
(Bx240064Na-RT-G1)*2
(Bx240064Na-RT-G1)*4
Battery capacity
6.4Ah
9.6Ah
12.8Ah
Runtime 50% Load
17min
9min
10min
9min
10min
Runtime 100% Load
6min
3min
3min
3min
3min
Charge time
≈1 hour
Intelligent battery
management
system(BMS)
Specific dual-level real-time monitoring of sodium-ion battery status, precise management of charging and discharging;
protect from over-charging/ over-discharging /over-temperature ; extend service lives ; WIFI remote monitoring (optional);
SYETEM FEATURES
Transfer time
Utility to Battery : 0ms; Utility to bypass: 0ms
Overload Line mode
105% < load ≤ 110%: transfer to bypass mode after 60 min
110% < load ≤ 125%: transfer to bypass mode after 10 min
125% < load ≤ 150%: transfer to bypass mode after 1 min
150% < load : transfer to bypass mode after 1.2sec
100% < load ≤ 110%: transfer to bypass mode after 10 min
110% < load ≤ 125%: transfer to bypass mode after 1 min
125% < load : transfer to bypass mode after 200 ms
Overload Bypass mode
130% overload for long term; >1000% overload for 100 ms
Temperature ≤ 30°C, load ≤ 135%: run for a long time
Temperature ≤ 40°C, load ≤ 125%: run for a long time
1000% load: run for 100 ms
Audible&Visual alarms
Fault, battery, bypass and normal
LCD
4.3-inch touchable
Interface communication
USB, RS485, Parallel, EPO Dry contact port, Maintenance breaker dry contact port,
Relay card(optional),SNMP card(optional), Battery temperature sentor(optional)
Interface communication
RS485,back-feed drive contact port, Output breaker dry contact port
RS485,Output breaker dry contact port,
battery breaker dry contact port,
back-feed or battery breaker drive contact port (optional)
Parallel function
Support, up to 4 units
ENVIRONMENT
Operating Temperature
-20-40℃
Recommonted operating Temperature
0-25℃
Storage Temperature
-20~50℃
Humidity range
0-95%(non-condensing)
Altitude
<1500m
Noise level
(from 1m distance)
<56dB
<58dB
<60dB
PHYSICAL
UPS dimension
(W*D*H)(mm)
440*680*131
Battery dimension
(W*D*H)(mm)
440*680*85
440*680*131
440*680*85
Battery dimension
(W*D*H)(mm)
440*680*85
440*680*131
440*680*85
Battery dimension
(W*D*H)(mm)
440*680*85
440*680*131
440*680*85
Battery Net weight(kg)
24
30
45
30
UPS & Battery
Net weight(kg)
73
85
116.5
148
STANDARD & CERTIFICATION
Intelligent port
RS232/USB port/SNMP card (optional)/Dry contact kit (optional)
Product specifications are subject to change without further notice.